Thursday, May 5, 2011

Inspection Processes Seminar at NY Guild Workshop

Tom will in Albany May 14th next Saturday, doing a seminar on Inspection Processes.  He will also have equipment and CDS there to show any one who is interested or just wants to see what’s new

The Seminar is being put on by the New York State Guild and being sponsored by Lindemann;  The Guild is asking for a donation of $25.00 per person per day ($50 per person for both days) be sent in with the registration form

Location: The Century House, 997 New London Road, Latham, NY 1211
Registration: Go to our www.nychimneysweepguild.org  - click the link for the
registration form under "Upcoming Events" -may be printed from
there.

May 14, Saturday
8:00 AM - 12:00 PM: Tom Urban on Tuning Up Your Inspections Processes (9:45 AM coffee break provided by Lindemann Chimney Supply).
12:00 PM - 1:00 PM: Lunch on your own
1:00 PM - 3:00 PM: Tom Urban on Tuning Up Your Inspections Processes
Someone in your company is CSIA certified, so this would be a great opportunity for them to get some CE credits.

(Chimney Industry News) Permanent link
I've received some questions about the upcoming Inspection Processes Seminar for the upcoming New York State Chimney Sweep Guild Workshop on May 14 (workshop dates are the 13 and 14).
Tom Urban, industry teacher and President of Estoban, has given me a more detailed outline on what his presentation will cover:
Photo Progression- Taking photos in the field that make sense and save time.
Archiving photos, now that you have them what do you do with them and how do you find them.
Financial side of inspections- understanding the cost involved and return.
Interpretation- what you see from chimney scans and how to present them.
Marketing side of inspections- educating your customer about their present chimney condition that shows a return.
May 14: Inspection Process Tune Up Seminar

CSIA CEUs: Technical 0.50
Communication & Liability 2.75
Business 1.25

NFI CEUs: 6 Elective


Accommodations:
Stay Inn
981 New Loudon Road
Cohoes, NY 12047
866-539-0036
. 
Holiday Inn Express Hotel & Suites
400 Old Loudon Road
Latham, NY 12110
(518) 783-6161

La Quinta Inn & Suites
Latham Albany Airport
833 New Loudon Rd
Latham, NY 12110
Phone: 1-518-640-2200

Hampton Inn & Suites Albany-Airport
45 British American Blvd.
Latham, NY 12110

Lindemann Warehouse Address:
Lindemann Chimney Supply
4 Airport Park Blvd.
Latham, NY 12110
Toll Free: 877-722-7230
Local Phone: 518-785-4922


Sunday, February 6, 2011

Smoking Fireplaces

Smoking fireplaces- You know the call is coming, and you reach into your bag of known sources and inevitable you forget to ask the right question or take a measurement that could lead to a solution. Smoking problems are costly and time consuming part of your customer service. Why not use the CDS to provide the checklist so when you need to focus on the problem all the facts are in front of you. We know smoking problems are out there (cough…. cough) we just want to help organize your thoughts.

Friday, November 12, 2010

Tips for the season:

DO NOT leave your Chim-Scan® in your truck or any vehicle over night.

 Do NOT leave it near a door or window, when in a building.

 Keep your Chim-Scan® at room temperature at all times.
Reasons: Just any other piece of electronic equipment Chim-Scans does not like dramatic temperature changes. Condensation builds up inside the unit and that only spells trouble.  Simply treat your Chim-Scan like you would treat yourself. IF your cold, it's getting cold. and the same with Heat. If this happens to you, open the case up and set out the unit (when possible) ant let it come to room temperature before you try to use it.

Practice setting up your Chim-Scan® before you take on a job, this will lower your frustration and you look more professional to your customers.
 
Do not hit the LCD screen, or leave anything on the reeler when closing the case. This will damage the screen and then it will have to be replaced.
 
If you have an AFT (auto focus tilt) camera, put in home position when putting it in or pulling it out of the chimney. If you don’t put it in home, you will break the tilt gears and or motor and it will have to be sent back for repair. 

 Do not unscrew the front camera reflector plate to change light bulbs! Read the manual that comes with your unit on how to change light bulbs. That’s what the small black tube is for. Rotate the tube Counterclockwise to remove the bulb; clockwise to tighten the new bulb.
 
For any other problems, check out our YouTube Videos.
Just go to www.youtube.com and search for ChimScan1643.

Wednesday, November 10, 2010

Quick and Easy Documentation


Digidal SD Card Recorder
Looking for a better way to gather photos from the interior of the chimney? We have created a way to capture images in a digital JPEG format simply WITH THE SNAP OF A BUTTON. The Chim-Scan’s digital SD card recorder provides 640 X 480 imagery, ready to be seen on a computer screen or sent directly to a computer printer. Plus, there aren’t any other cables or power supplies to add.
Just plug into the Chim-Scan® controller, then plug the other end into the camera cable and you’re ready to go. The power, "video in", and "video out" issues are already switched, so the images projected onto the LCD screen or older monitor is done. Press the mode button to view the images you’ve taken to be sure they’re what you need and the photos are ready for the computer or printer. The unit holds an SD card up to a 2G, with plenty of room for your photos.
This unit can be added to older Chim-Scan® built since 1995. An additional LED light may need to be added to the older units. Or can be added into the Series 200 controller, ready to take photos of the chimney interior. Just ask yourLindemann Representative about this quick and easy affordable upgrade for your Chim-Scan® system. You'll be on the road to greater profits and outstanding documentation!
Digital Card Reader

Chim-Scan® Saves the day


During our first blizzard of the season, not only were we dealing blowing snow and frigid weather but one of the circulators for the "in floor radiant heat" decided to quit.
NO problem. Our neighbor has a plumbing business, so I skated over in the van and got a new one. Then there was air in the pipes, so now the fun begins. We have had this heating system for 13 years and we had not needed to bleed any of the lines. Of course the one that was needed had been framed in behind one of our office desks, computer, etc.
Estoban Office Wall 1 
No problem, after drilling a hole into the wall board, we figured it would be a great place to hang that new calendar we got at the local China Buffet restaurant. :-) 
This six inch hole seemed big enough to reach in and attach the hose. Oh yeah, we had to find the hose out in the snow and get that thawed first. Yes, I know that should have already been done before this storm, but we had been busy!!
Estoban Office Wall With 6 Hole 
So what does all this have to do with cameras? Now for the rest of the story: There were two valves inside the wall cavity up by the ceiling. So we covered the desk with a sheet to keep any debris from the UPS printer, the Dymo labeler, the speakers, the adding machine, the LCD monitor, the electric pencil sharper, the telephone, gosh there are a lot of important items on Mary’s desk.
As I’m standing on the desk straddling the monitor, I reached in and tried to attach the hose. Oh, did I mention, I’m suffering from “ tennis elbow” this week and I can barely lift my arm and it has no strength in it. Hey, Esther can you help with this?
Sure, she said, but the flash light does not illuminate the area with my arm in the hole. Gosh sometimes she acts like such a “girl”. So, see photo, we drilled another hole in the wall, inserted the Enviro-Flex Camera, then put theChim-Scan case with the monitor on top of the cupboard over the desk.
Estoban Office Wall Clos-Up 
Golly, look at what we could see!! We now could easily attach the hose, bleed the water line and then, hopefully the hot water would be in the floor. Soon all the office furniture will be warmed up again and Esther’s knees will no longer be like ice cubes!.
So the Chim-Scan Cameras can be used for a variety uses besides interior chimney inspections. So let your imagination run wild!!
(This was last winter.)

Thursday, November 4, 2010

Four Pathways to Chimney Damage

Four Pathways to Chimney Damage.
In the course of your day to day field observations on chimneys, the customer may question on how or where damage originated from. Sometimes it appears to be a chicken and egg situation. Did the crown wear out and let water in, that started the spalling of brick and mortar, or did the mortar weaken first, letting the crown to settle causing the crown to crack letting even more water in. Or does the mortar hold the bricks together or does it hold them apart? This might be a good debate at a convention but when you’re standing in front of a customer, the bottom line is somebody needs repair work done, and you don’t have all day to explain it to them.

The ability to explain to the customer a logical process how it all happened and the consequences of the disrepair can be the difference whether you are doing the repair work or someone else is. The worst case scenario is you don’t make the repair compelling enough for them to take action, without the drama and sales scare tactics many resort to.

Then the situation gets complicated when your customer asked the age-old question whether their chimney is safe to use or not. You the field technician, are strapped with the concept of how all this happened and try to place a timeline on this, and ultimately what the cost to repair is going to be.

The best way I’ve found to uncomplicate all the many minor or major deficiencies that all of us see, I learned to break it down into four principal pathways that destroy chimneys. You might have a chimney with open more joints, a worn crown, and an abused rain cover. It comes down to the age-old question of how to eat an elephant; one bite at a time.

The first pathway is latent defects. Those are the defects that were built into the system at the time of the installation, that are usually not seen readily. Although manufactured systems such as prefabricated fireplaces and chimney pipe are designed and built at a factory with an installation guide, many of us have seen where creative uses of the material or poor workmanship have caused material not to be in its ideal condition. With masonry, the list can be long, hearth extensions, firebox limitations, dampers that are inoperative, unparged smoke chambers, and then the liners, open mortar joints, missing liners etc.

The second pathway is from regular wear and tear. This is the time to chimney has spent exposed to outdoor temperature swings, or interior temperature swings have caused a chimney to wear out over of time.

The third pathway is moisture. Of all the pathways this one can create the most havoc. It can be very subtle, and yet totally destroy chimney over a period of time.

The last pathway is from a sudden occurrence. Usually in the form of a lightning strike, an appliance malfunction, high temperature fluctuations like a chimney fire, and other assorted events that appear sudden.

By breaking down chimney degradation into four pathways provides me a way of putting things into perspective for the customer. Because many times you will see all four pathways into one system at one time. Because of one deficiency can lead to another deficiency and to another, so by breaking it down I can explain to the customer how it all happened and where they need to concentrate  their efforts especially when the repair will need to be done in stages, whether monetary or climate considerations.
More on this subject to come. 

Friday, February 19, 2010

Chimney Inspections for Busy People

Ok, maybe you know about NFPA 211 Chapter 14. Maybe you don't. The bottom line is you should. Wouldn’t it be better to say to yourself, how I can fulfill the Level 1 and Level 2 process and do it in a time frame that doesn’t take all day! And how can I review the items listed in each installation. That’s where Chimney Data System (C.D.S.) comes in. We have looked at the NFPA 211 Chapter 14 Annex and recategorized and sorted the list, placing the recommended items into various installation scenarios and then reviewed the list of items in 14-4 to create a path for the tech to follow. Now the recommended items listed can be inspected in context with the installation. This approach provides a better way to fulfill the 14-4. and help stop missed items.

Have you ever found an installion that is the same? NO!! But do you see the same thing is various installations. This may sound trivial, but it had stopped many companies from completing a full level 1 or 2. Or you have the information from the level 1, but it is in a Bad Place-your head!

We sorted through the Annex and found the same items that needs checking and prioritized them to create a path for the tech to follow. Following the path you are less likely to forget to check something. The big bonus in time comes when the techs paperwork comes back to the office, the office staff uses the same procedure to process the paperwork. Now the office doesn’t have to hunt down the tech to do a “Spock mind-meld” with them. The time saved within a month can be worth thousands of dollars, plus reports or comments about the homeowner’s installation can be done much faster. With the changes in technology and media advancements and because the C.D.S. is in a MS Office or Open Office format, you can take advantage of all the new Wi-Fi 3G computer thingy’s or just print out the C.D.S. guide for the specific installation on to a piece of paper and fill in the questions. How you want to transmit the data is only limited to your imagination and technology. CDS provides the backbone to complete the Level 1 and 2 inspection required by NFPA 211 Chapter 14.